Фрагмент документа "ДИРЕКТИВА СОВЕТА N 1999/31/ЕС ПО ПОЛИГОНАМ ЗАХОРОНЕНИЯ ОТХОДОВ".
B. Monitoring The parameters to be analysed in the samples taken must be derived from the expected composition of the leachate and the groundwater quality in the area. In selecting the parameters for analysis account should be taken of mobility in the groundwater zone. Parameters could include indicator parameters in order to ensure an early recognition of change in water quality <*>. -------------------------------- <*> Recommended parameters: ph, TOC, phenols, heavy metals, fluoride, AS, oil/hydrocarbons. ------------------------------------------------------------------ | | Operation phase | After-care phase | |---------------------|--------------------|---------------------| |Level of groundwater |every six months <1>|every six months <1> | |---------------------|--------------------|---------------------| |Groundwater |site-specific |site-specific | |composition |frequency <2> <3> |frequency <2> <3> | ------------------------------------------------------------------ -------------------------------- <1> If there are fluctuating groundwater levels, the frequency must be increased. <2> The frequency must be based on possibility for remedial actions between two samplings if a trigger level is reached, i.e. the frequency must be determined on the basis of knowledge and the evaluation of the velocity of groundwater flow. <3> When a trigger level is reached (see C), verification is necessary by repeating the sampling. When the level has been confirmed, a contingency plan (laid down in the permit) must be followed. |
Фрагмент документа "ДИРЕКТИВА СОВЕТА N 1999/31/ЕС ПО ПОЛИГОНАМ ЗАХОРОНЕНИЯ ОТХОДОВ".